535 lines
19 KiB
Transact-SQL
535 lines
19 KiB
Transact-SQL
--Migration
|
|
PRINT N'Creating [dbo].[T_CONFIGTIPUS]...';
|
|
|
|
|
|
GO
|
|
CREATE TABLE [dbo].[T_CONFIGTIPUS] (
|
|
[ID] INT IDENTITY (1, 1) NOT NULL,
|
|
[C_CONFIG] VARCHAR (80) NOT NULL,
|
|
[C_MODUL] VARCHAR (80) NOT NULL,
|
|
[TOROLT] CHAR (1) NOT NULL,
|
|
[SERIAL] INT NOT NULL,
|
|
[LASTCHANGED] DATETIME NOT NULL,
|
|
[CREATED] DATETIME NOT NULL,
|
|
[MODIFIER] INT NULL,
|
|
[CREATOR] INT NULL,
|
|
[ELOZOTANEVIREKORDID] INT NULL,
|
|
CONSTRAINT [PK_ConfigTipus] PRIMARY KEY CLUSTERED ([ID] ASC)
|
|
);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]...';
|
|
|
|
|
|
GO
|
|
CREATE TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY] (
|
|
[ID] INT IDENTITY (1, 1) NOT NULL,
|
|
[C_ELEKTRONIKUSPELDANYID] INT NULL,
|
|
[C_FAILEDJOBID] INT NULL,
|
|
[C_IKTATOTTDOKUMENTUMID] INT NOT NULL,
|
|
[C_FILEID] INT NULL,
|
|
[C_INTEZMENYID] INT NOT NULL,
|
|
[C_TANEVID] INT NOT NULL,
|
|
[TOROLT] CHAR (1) NOT NULL,
|
|
[SERIAL] INT NOT NULL,
|
|
[LASTCHANGED] DATETIME NOT NULL,
|
|
[CREATED] DATETIME NOT NULL,
|
|
[MODIFIER] INT NULL,
|
|
[CREATOR] INT NULL,
|
|
[ELOZOTANEVIREKORDID] INT NULL,
|
|
CONSTRAINT [PK_IktatottDokumentumCsatolmany] PRIMARY KEY CLUSTERED ([ID] ASC)
|
|
);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[NCI_IktatottDokumentumCsatolmany_IktatottDokumentumId]...';
|
|
|
|
|
|
GO
|
|
CREATE NONCLUSTERED INDEX [NCI_IktatottDokumentumCsatolmany_IktatottDokumentumId]
|
|
ON [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]([C_IKTATOTTDOKUMENTUMID] ASC);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[NCI_IktatottDokumentumCsatolmany_FileId]...';
|
|
|
|
|
|
GO
|
|
CREATE NONCLUSTERED INDEX [NCI_IktatottDokumentumCsatolmany_FileId]
|
|
ON [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]([C_FILEID] ASC);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[NCI_IktatottDokumentumCsatolmany_IntezmenyId]...';
|
|
|
|
|
|
GO
|
|
CREATE NONCLUSTERED INDEX [NCI_IktatottDokumentumCsatolmany_IntezmenyId]
|
|
ON [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]([C_INTEZMENYID] ASC);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[NCI_IktatottDokumentumCsatolmany_TanevId]...';
|
|
|
|
|
|
GO
|
|
CREATE NONCLUSTERED INDEX [NCI_IktatottDokumentumCsatolmany_TanevId]
|
|
ON [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]([C_TANEVID] ASC);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG]...';
|
|
|
|
|
|
GO
|
|
CREATE TABLE [dbo].[T_INTEZMENYCONFIG] (
|
|
[ID] INT IDENTITY (1, 1) NOT NULL,
|
|
[C_ERTEK] NVARCHAR (255) NULL,
|
|
[C_CONFIGTIPUSID] INT NOT NULL,
|
|
[C_INTEZMENYID] INT NOT NULL,
|
|
[TOROLT] CHAR (1) NOT NULL,
|
|
[SERIAL] INT NOT NULL,
|
|
[LASTCHANGED] DATETIME NOT NULL,
|
|
[CREATED] DATETIME NOT NULL,
|
|
[MODIFIER] INT NULL,
|
|
[CREATOR] INT NULL,
|
|
[ELOZOTANEVIREKORDID] INT NULL,
|
|
CONSTRAINT [PK_IntezmenyConfig] PRIMARY KEY CLUSTERED ([ID] ASC)
|
|
);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG].[NCI_IntezmenyConfig_ConfigTipusId]...';
|
|
|
|
|
|
GO
|
|
CREATE NONCLUSTERED INDEX [NCI_IntezmenyConfig_ConfigTipusId]
|
|
ON [dbo].[T_INTEZMENYCONFIG]([C_CONFIGTIPUSID] ASC);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG].[NCI_IntezmenyConfig_IntezmenyId]...';
|
|
|
|
|
|
GO
|
|
CREATE NONCLUSTERED INDEX [NCI_IntezmenyConfig_IntezmenyId]
|
|
ON [dbo].[T_INTEZMENYCONFIG]([C_INTEZMENYID] ASC);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_CONFIGTIPUS]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_CONFIGTIPUS]
|
|
ADD DEFAULT ((0)) FOR [SERIAL];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_CONFIGTIPUS]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_CONFIGTIPUS]
|
|
ADD DEFAULT (getdate()) FOR [CREATED];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_CONFIGTIPUS]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_CONFIGTIPUS]
|
|
ADD DEFAULT (getdate()) FOR [LASTCHANGED];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_CONFIGTIPUS]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_CONFIGTIPUS]
|
|
ADD DEFAULT ('F') FOR [TOROLT];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]
|
|
ADD DEFAULT ('F') FOR [TOROLT];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]
|
|
ADD DEFAULT ((0)) FOR [SERIAL];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]
|
|
ADD DEFAULT (getdate()) FOR [LASTCHANGED];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY]
|
|
ADD DEFAULT (getdate()) FOR [CREATED];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_INTEZMENYCONFIG]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_INTEZMENYCONFIG]
|
|
ADD DEFAULT ('F') FOR [TOROLT];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_INTEZMENYCONFIG]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_INTEZMENYCONFIG]
|
|
ADD DEFAULT ((0)) FOR [SERIAL];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_INTEZMENYCONFIG]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_INTEZMENYCONFIG]
|
|
ADD DEFAULT (getdate()) FOR [CREATED];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating unnamed constraint on [dbo].[T_INTEZMENYCONFIG]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_INTEZMENYCONFIG]
|
|
ADD DEFAULT (getdate()) FOR [LASTCHANGED];
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[FK_IktatottDokumentumCsatolmany_IktatottDokumentumId_REF_IktatottDokumentum]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY] WITH NOCHECK
|
|
ADD CONSTRAINT [FK_IktatottDokumentumCsatolmany_IktatottDokumentumId_REF_IktatottDokumentum] FOREIGN KEY ([C_IKTATOTTDOKUMENTUMID]) REFERENCES [dbo].[T_IKTATOTTDOKUMENTUM] ([ID]);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[FK_IktatottDokumentumCsatolmany_FileId_REF_File]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY] WITH NOCHECK
|
|
ADD CONSTRAINT [FK_IktatottDokumentumCsatolmany_FileId_REF_File] FOREIGN KEY ([C_FILEID]) REFERENCES [dbo].[T_FILE] ([ID]);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[FK_IktatottDokumentumCsatolmany_IntezmenyId_REF_Intezmeny]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY] WITH NOCHECK
|
|
ADD CONSTRAINT [FK_IktatottDokumentumCsatolmany_IntezmenyId_REF_Intezmeny] FOREIGN KEY ([C_INTEZMENYID]) REFERENCES [dbo].[T_INTEZMENY] ([ID]);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[FK_IktatottDokumentumCsatolmany_TanevId_REF_Tanev]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY] WITH NOCHECK
|
|
ADD CONSTRAINT [FK_IktatottDokumentumCsatolmany_TanevId_REF_Tanev] FOREIGN KEY ([C_TANEVID]) REFERENCES [dbo].[T_TANEV] ([ID]);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[FK_IntezmenyConfig_ConfigTipusId_REF_ConfigTipus]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_INTEZMENYCONFIG] WITH NOCHECK
|
|
ADD CONSTRAINT [FK_IntezmenyConfig_ConfigTipusId_REF_ConfigTipus] FOREIGN KEY ([C_CONFIGTIPUSID]) REFERENCES [dbo].[T_CONFIGTIPUS] ([ID]);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[FK_IntezmenyConfig_IntezmenyId_REF_Intezmeny]...';
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_INTEZMENYCONFIG] WITH NOCHECK
|
|
ADD CONSTRAINT [FK_IntezmenyConfig_IntezmenyId_REF_Intezmeny] FOREIGN KEY ([C_INTEZMENYID]) REFERENCES [dbo].[T_INTEZMENY] ([ID]);
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_CONFIGTIPUS].[ID].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord egyedi azonosítója, generált IDENTITY(1, 1) (kivéve altáblák esetén, ahol a főtábla ID-ját kapja)', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_CONFIGTIPUS', @level2type = N'COLUMN', @level2name = N'ID';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_CONFIGTIPUS].[TOROLT].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord logikai töröltségét jelző flag', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_CONFIGTIPUS', @level2type = N'COLUMN', @level2name = N'TOROLT';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_CONFIGTIPUS].[SERIAL].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Minden C# kódból történő módosítás esetén eggyel nő az értéke. Hogy párhuzamos módosítás esetnán ne íródjanak felül az adatok', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_CONFIGTIPUS', @level2type = N'COLUMN', @level2name = N'SERIAL';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_CONFIGTIPUS].[LASTCHANGED].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N' A rekord utolsó módosításának időpontja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_CONFIGTIPUS', @level2type = N'COLUMN', @level2name = N'LASTCHANGED';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_CONFIGTIPUS].[CREATED].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord létrehozásának időpontja ', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_CONFIGTIPUS', @level2type = N'COLUMN', @level2name = N'CREATED';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_CONFIGTIPUS].[MODIFIER].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot utoljára módosító felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_CONFIGTIPUS', @level2type = N'COLUMN', @level2name = N'MODIFIER';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_CONFIGTIPUS].[CREATOR].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot létrehozó felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_CONFIGTIPUS', @level2type = N'COLUMN', @level2name = N'CREATOR';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_CONFIGTIPUS].[ELOZOTANEVIREKORDID].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord előző tanévben lévő ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_CONFIGTIPUS', @level2type = N'COLUMN', @level2name = N'ELOZOTANEVIREKORDID';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[ID].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord egyedi azonosítója, generált IDENTITY(1, 1) (kivéve altáblák esetén, ahol a főtábla ID-ját kapja)', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_IKTATOTTDOKUMENTUMCSATOLMANY', @level2type = N'COLUMN', @level2name = N'ID';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[C_INTEZMENYID].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Az intézmény ID-ja, amihez a rekord tartozik', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_IKTATOTTDOKUMENTUMCSATOLMANY', @level2type = N'COLUMN', @level2name = N'C_INTEZMENYID';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[C_TANEVID].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A tanév ID-ja, amihez a rekord tartozik', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_IKTATOTTDOKUMENTUMCSATOLMANY', @level2type = N'COLUMN', @level2name = N'C_TANEVID';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[TOROLT].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord logikai töröltségét jelző flag', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_IKTATOTTDOKUMENTUMCSATOLMANY', @level2type = N'COLUMN', @level2name = N'TOROLT';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[SERIAL].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Minden C# kódból történő módosítás esetén eggyel nő az értéke. Hogy párhuzamos módosítás esetnán ne íródjanak felül az adatok', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_IKTATOTTDOKUMENTUMCSATOLMANY', @level2type = N'COLUMN', @level2name = N'SERIAL';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[LASTCHANGED].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N' A rekord utolsó módosításának időpontja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_IKTATOTTDOKUMENTUMCSATOLMANY', @level2type = N'COLUMN', @level2name = N'LASTCHANGED';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[CREATED].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord létrehozásának időpontja ', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_IKTATOTTDOKUMENTUMCSATOLMANY', @level2type = N'COLUMN', @level2name = N'CREATED';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[MODIFIER].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot utoljára módosító felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_IKTATOTTDOKUMENTUMCSATOLMANY', @level2type = N'COLUMN', @level2name = N'MODIFIER';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[CREATOR].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot létrehozó felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_IKTATOTTDOKUMENTUMCSATOLMANY', @level2type = N'COLUMN', @level2name = N'CREATOR';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY].[ELOZOTANEVIREKORDID].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord előző tanévben lévő ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_IKTATOTTDOKUMENTUMCSATOLMANY', @level2type = N'COLUMN', @level2name = N'ELOZOTANEVIREKORDID';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG].[ID].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord egyedi azonosítója, generált IDENTITY(1, 1) (kivéve altáblák esetén, ahol a főtábla ID-ját kapja)', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_INTEZMENYCONFIG', @level2type = N'COLUMN', @level2name = N'ID';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG].[C_INTEZMENYID].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Az intézmény ID-ja, amihez a rekord tartozik', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_INTEZMENYCONFIG', @level2type = N'COLUMN', @level2name = N'C_INTEZMENYID';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG].[TOROLT].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord logikai töröltségét jelző flag', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_INTEZMENYCONFIG', @level2type = N'COLUMN', @level2name = N'TOROLT';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG].[SERIAL].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Minden C# kódból történő módosítás esetén eggyel nő az értéke. Hogy párhuzamos módosítás esetnán ne íródjanak felül az adatok', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_INTEZMENYCONFIG', @level2type = N'COLUMN', @level2name = N'SERIAL';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG].[LASTCHANGED].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N' A rekord utolsó módosításának időpontja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_INTEZMENYCONFIG', @level2type = N'COLUMN', @level2name = N'LASTCHANGED';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG].[CREATED].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord létrehozásának időpontja ', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_INTEZMENYCONFIG', @level2type = N'COLUMN', @level2name = N'CREATED';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG].[MODIFIER].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot utoljára módosító felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_INTEZMENYCONFIG', @level2type = N'COLUMN', @level2name = N'MODIFIER';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG].[CREATOR].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot létrehozó felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_INTEZMENYCONFIG', @level2type = N'COLUMN', @level2name = N'CREATOR';
|
|
|
|
|
|
GO
|
|
PRINT N'Creating [dbo].[T_INTEZMENYCONFIG].[ELOZOTANEVIREKORDID].[MS_Description]...';
|
|
|
|
|
|
GO
|
|
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord előző tanévben lévő ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_INTEZMENYCONFIG', @level2type = N'COLUMN', @level2name = N'ELOZOTANEVIREKORDID';
|
|
|
|
|
|
|
|
|
|
|
|
GO
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY] WITH CHECK CHECK CONSTRAINT [FK_IktatottDokumentumCsatolmany_IktatottDokumentumId_REF_IktatottDokumentum];
|
|
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY] WITH CHECK CHECK CONSTRAINT [FK_IktatottDokumentumCsatolmany_FileId_REF_File];
|
|
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY] WITH CHECK CHECK CONSTRAINT [FK_IktatottDokumentumCsatolmany_IntezmenyId_REF_Intezmeny];
|
|
|
|
ALTER TABLE [dbo].[T_IKTATOTTDOKUMENTUMCSATOLMANY] WITH CHECK CHECK CONSTRAINT [FK_IktatottDokumentumCsatolmany_TanevId_REF_Tanev];
|
|
|
|
ALTER TABLE [dbo].[T_INTEZMENYCONFIG] WITH CHECK CHECK CONSTRAINT [FK_IntezmenyConfig_ConfigTipusId_REF_ConfigTipus];
|
|
|
|
ALTER TABLE [dbo].[T_INTEZMENYCONFIG] WITH CHECK CHECK CONSTRAINT [FK_IntezmenyConfig_IntezmenyId_REF_Intezmeny];
|
|
|
|
|
|
GO
|
|
PRINT N'Update complete.';
|
|
|
|
|
|
GO
|
|
|
|
|
|
EXEC dev.uspCreateSchemaViews 'T_IKTATOTTDOKUMENTUMCSATOLMANY, T_INTEZMENYCONFIG, T_CONFIGTIPUS'
|
|
GO
|
|
|
|
EXEC dev.sp_Global_GenerateAsyncAuditTriggerAll
|
|
GO
|
|
|
|
ALTER QUEUE auditLog.[AuditQueue]
|
|
WITH ACTIVATION (
|
|
STATUS = ON,
|
|
PROCEDURE_NAME = auditLog.usp_AuditProcessing,
|
|
MAX_QUEUE_READERS = 10,
|
|
EXECUTE AS 'Kreta_tech_user'
|
|
);
|
|
GO
|