Files
kreta/Kreta.DataAccess.Migrations/Scripts/Archive/20190531024514_KRETA_8173/alterAndCreateTables.sql
2024-03-13 00:33:46 +01:00

396 lines
13 KiB
Transact-SQL

GO
SET ANSI_NULLS, ANSI_PADDING, ANSI_WARNINGS, ARITHABORT, CONCAT_NULL_YIELDS_NULL, QUOTED_IDENTIFIER ON;
SET NUMERIC_ROUNDABORT OFF;
GO
PRINT N'Altering [dbo].[T_DASHBOARDUZENET]...';
GO
ALTER TABLE [dbo].[T_DASHBOARDUZENET]
ADD [C_ISPOPUP] CHAR (1) DEFAULT ('F') NOT NULL,
[C_POPUPGYAKORISAGAPERCBEN] INT NULL;
GO
PRINT N'Altering [dbo].[T_ERTEKELESMOD]...';
GO
ALTER TABLE [dbo].[T_ERTEKELESMOD]
ADD [C_ISSZAMONKERESKORLATOZOTT] CHAR (1) DEFAULT ('F') NOT NULL;
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO]...';
GO
CREATE TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO] (
[ID] INT IDENTITY (1, 1) NOT NULL,
[C_MEGJELENITESEKSZAMA] INT NOT NULL,
[C_UTOLSOMEGTEKINTESIDEJE] DATETIME NULL,
[C_EGYEDIMUVELET] NVARCHAR (255) NULL,
[C_DASHBOARDUZENETID] INT NOT NULL,
[C_FELHASZNALOID] INT NOT NULL,
[C_INTEZMENYID] INT NOT NULL,
[C_TANEVID] INT NOT NULL,
[TOROLT] CHAR (1) NOT NULL,
[SERIAL] INT NOT NULL,
[LASTCHANGED] DATETIME NOT NULL,
[CREATED] DATETIME NOT NULL,
[MODIFIER] INT NULL,
[CREATOR] INT NULL,
[ELOZOTANEVIREKORDID] INT NULL,
[NNID] INT NULL,
CONSTRAINT [PK_T_4028916] PRIMARY KEY CLUSTERED ([ID] ASC)
);
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[I_T_4028922_4028920]...';
GO
CREATE NONCLUSTERED INDEX [I_T_4028922_4028920]
ON [dbo].[T_DASHBOARDUZENETFELHASZNALO]([C_DASHBOARDUZENETID] ASC);
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[I_T_4028925_4028923]...';
GO
CREATE NONCLUSTERED INDEX [I_T_4028925_4028923]
ON [dbo].[T_DASHBOARDUZENETFELHASZNALO]([C_FELHASZNALOID] ASC);
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[I_T_402891602_402891600]...';
GO
CREATE NONCLUSTERED INDEX [I_T_402891602_402891600]
ON [dbo].[T_DASHBOARDUZENETFELHASZNALO]([C_INTEZMENYID] ASC);
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[I_T_402891605_402891603]...';
GO
CREATE NONCLUSTERED INDEX [I_T_402891605_402891603]
ON [dbo].[T_DASHBOARDUZENETFELHASZNALO]([C_TANEVID] ASC);
GO
PRINT N'Creating unnamed constraint on [dbo].[T_DASHBOARDUZENETFELHASZNALO]...';
GO
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO]
ADD DEFAULT ('F') FOR [TOROLT];
GO
PRINT N'Creating unnamed constraint on [dbo].[T_DASHBOARDUZENETFELHASZNALO]...';
GO
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO]
ADD DEFAULT ((0)) FOR [C_MEGJELENITESEKSZAMA];
GO
PRINT N'Creating unnamed constraint on [dbo].[T_DASHBOARDUZENETFELHASZNALO]...';
GO
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO]
ADD DEFAULT (getdate()) FOR [LASTCHANGED];
GO
PRINT N'Creating unnamed constraint on [dbo].[T_DASHBOARDUZENETFELHASZNALO]...';
GO
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO]
ADD DEFAULT ((0)) FOR [SERIAL];
GO
PRINT N'Creating unnamed constraint on [dbo].[T_DASHBOARDUZENETFELHASZNALO]...';
GO
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO]
ADD DEFAULT (getdate()) FOR [CREATED];
GO
PRINT N'Creating [dbo].[FK_4028922_4028920]...';
GO
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO] WITH NOCHECK
ADD CONSTRAINT [FK_4028922_4028920] FOREIGN KEY ([C_DASHBOARDUZENETID]) REFERENCES [dbo].[T_DASHBOARDUZENET] ([ID]);
GO
PRINT N'Creating [dbo].[FK_4028925_4028923]...';
GO
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO] WITH NOCHECK
ADD CONSTRAINT [FK_4028925_4028923] FOREIGN KEY ([C_FELHASZNALOID]) REFERENCES [dbo].[T_FELHASZNALO] ([ID]);
GO
PRINT N'Creating [dbo].[FK_402891602_402891600]...';
GO
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO] WITH NOCHECK
ADD CONSTRAINT [FK_402891602_402891600] FOREIGN KEY ([C_INTEZMENYID]) REFERENCES [dbo].[T_INTEZMENY] ([ID]);
GO
PRINT N'Creating [dbo].[FK_402891605_402891603]...';
GO
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO] WITH NOCHECK
ADD CONSTRAINT [FK_402891605_402891603] FOREIGN KEY ([C_TANEVID]) REFERENCES [dbo].[T_TANEV] ([ID]);
GO
PRINT N'Refreshing [dbo].[T_ERTEKELESMOD_OSSZES]...';
GO
EXECUTE sp_refreshsqlmodule N'[dbo].[T_ERTEKELESMOD_OSSZES]';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[ID].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord egyedi azonosítója, generált IDENTITY(1, 1) (kivéve altáblák esetén, ahol a főtábla ID-ját kapja)', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'ID';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[C_MEGJELENITESEKSZAMA].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Megjelenítések száma', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'C_MEGJELENITESEKSZAMA';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[C_UTOLSOMEGTEKINTESIDEJE].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Utolsó megtekintés ideje', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'C_UTOLSOMEGTEKINTESIDEJE';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[C_EGYEDIMUVELET].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Egyedi muvelet', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'C_EGYEDIMUVELET';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[C_INTEZMENYID].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Az intézmény ID-ja, amihez a rekord tartozik', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'C_INTEZMENYID';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[C_TANEVID].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A tanév ID-ja, amihez a rekord tartozik', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'C_TANEVID';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[TOROLT].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord logikai töröltségét jelző flag', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'TOROLT';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[SERIAL].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Minden C# kódból történő módosítás esetén eggyel nő az értéke. Hogy párhuzamos módosítás esetnán ne íródjanak felül az adatok', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'SERIAL';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[LASTCHANGED].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N' A rekord utolsó módosításának időpontja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'LASTCHANGED';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[CREATED].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord létrehozásának időpontja ', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'CREATED';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[MODIFIER].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot utoljára módosító felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'MODIFIER';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[CREATOR].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot létrehozó felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'CREATOR';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[ELOZOTANEVIREKORDID].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord előző tanévben lévő ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'ELOZOTANEVIREKORDID';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENETFELHASZNALO].[NNID].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord régi, Neptun Naplóban lévő ID-ja. (migrációval került be)', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENETFELHASZNALO', @level2type = N'COLUMN', @level2name = N'NNID';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENET].[C_ISPOPUP].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Popup-ban jelenjen meg?', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENET', @level2type = N'COLUMN', @level2name = N'C_ISPOPUP';
GO
PRINT N'Creating [dbo].[T_DASHBOARDUZENET].[C_POPUPGYAKORISAGAPERCBEN].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Popup megjelenésének gyakorisága percben', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENET', @level2type = N'COLUMN', @level2name = N'C_POPUPGYAKORISAGAPERCBEN';
GO
PRINT N'Creating [dbo].[T_ERTEKELESMOD].[C_ISSZAMONKERESKORLATOZOTT].[MS_Description]...';
GO
EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Korlátozott számonkérés?', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_ERTEKELESMOD', @level2type = N'COLUMN', @level2name = N'C_ISSZAMONKERESKORLATOZOTT';
GO
PRINT N'Refreshing [dbo].[sp_GetPedagogusAltalAdottErtekelesek]...';
GO
EXECUTE sp_refreshsqlmodule N'[dbo].[sp_GetPedagogusAltalAdottErtekelesek]';
GO
PRINT N'Refreshing [dbo].[sp_Global_CreateDictionaryItems]...';
GO
EXECUTE sp_refreshsqlmodule N'[dbo].[sp_Global_CreateDictionaryItems]';
GO
PRINT N'Checking existing data against newly created constraints';
GO
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO] WITH CHECK CHECK CONSTRAINT [FK_4028922_4028920];
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO] WITH CHECK CHECK CONSTRAINT [FK_4028925_4028923];
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO] WITH CHECK CHECK CONSTRAINT [FK_402891602_402891600];
ALTER TABLE [dbo].[T_DASHBOARDUZENETFELHASZNALO] WITH CHECK CHECK CONSTRAINT [FK_402891605_402891603];
GO
PRINT N'Update complete.';
GO
EXEC dev.sp_Global_GenerateAsyncAuditTriggerAll
GO
ALTER QUEUE auditLog.[AuditQueue]
WITH ACTIVATION
(
STATUS = ON,
PROCEDURE_NAME = auditLog.usp_AuditProcessing,
MAX_QUEUE_READERS = 10,
EXECUTE AS 'Kreta_tech_user'
);
GO
--------------------
PRINT '--- intézményi view-k (dbo táblákkal megegyezõ nevû és a tábla_OSSZES nevûek) frissítése ---'
DECLARE @viewname nvarchar(100), @pureview nvarchar(100)
DECLARE semaviewk CURSOR LOCAL FOR
SELECT '['+TABLE_SCHEMA + '].[' + TABLE_NAME + ']', TABLE_NAME
FROM INFORMATION_SCHEMA.TABLES
WHERE TABLE_TYPE = 'VIEW' and TABLE_SCHEMA LIKE 'KR[_]%[_]Schema'
AND TABLE_NAME in ('T_DASHBOARDUZENET', 'T_DASHBOARDUZENET_OSSZES',
'T_ERTEKELESMOD', 'T_ERTEKELESMOD_OSSZES') -- ha csak néhány VIEW frissült, akkor a gyorsabb futásért ide fel lehet sorolni
ORDER BY TABLE_SCHEMA, TABLE_NAME
OPEN semaviewk
FETCH NEXT FROM semaviewk INTO @viewname, @pureview
WHILE @@FETCH_STATUS = 0 BEGIN
PRINT @viewname
EXEC sp_refreshview @viewname
FETCH NEXT FROM semaviewk INTO @viewname, @pureview
END
CLOSE semaviewk
DEALLOCATE semaviewk
GO