--Migration GO PRINT N'Dropping unnamed constraints...'; DECLARE @sql nvarchar(max) = '' SELECT @sql += CONCAT('ALTER TABLE ' , OBJECT_NAME(c.object_id) , ' DROP CONSTRAINT ' , dc.name + ';' + char(13) + char(10)) FROM sys.default_constraints dc INNER JOIN sys.columns c ON c.column_id = dc.parent_column_id AND dc.parent_object_id = c.object_id WHERE c.name = 'C_ISERTESITESELKULDVE' AND OBJECT_NAME(c.object_id) IN ('T_HAZIFELADATOK', 'T_SZAMONKERESELOREJELZES', 'T_TANULOHAZIFELADAT') EXEC sp_executesql @sql GO PRINT N'Dropping [dbo].[FK_TanuloEsemeny_FeljegyzoId_REF_Alkalmazott]...'; GO GO ALTER TABLE [dbo].[T_TANULOESEMENY] DROP CONSTRAINT IF EXISTS [FK_TanuloEsemeny_FeljegyzoId_REF_Alkalmazott]; GO ALTER TABLE [dbo].[T_TANULOESEMENY] DROP CONSTRAINT IF EXISTS [FK_TanuloEsemeny_FeljegyzoId_REF_Felhasznalo]; GO PRINT N'Altering [dbo].[T_HAZIFELADATOK]...'; GO ALTER TABLE [dbo].[T_HAZIFELADATOK] ADD [C_ORARENDIORAGROUPID] INT NULL; GO PRINT N'Altering [dbo].[T_OSZTALY]...'; GO ALTER TABLE [dbo].[T_OSZTALY] ADD [C_ARANYJANOSPROGRAMTIPUSID] INT NULL; GO PRINT N'Creating [dbo].[T_OSZTALY].[NCI_Osztaly_AlintezmenyId_AltanevId_AranyJanosProgramTipusId]...'; GO CREATE NONCLUSTERED INDEX [NCI_Osztaly_AlintezmenyId_AltanevId_AranyJanosProgramTipusId] ON [dbo].[T_OSZTALY]([C_ALINTEZMENYID] ASC, [C_ALTANEVID] ASC, [C_ARANYJANOSPROGRAMTIPUSID] ASC); GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ]...'; GO CREATE TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] ( [ID] INT IDENTITY (1, 1) NOT NULL, [C_ISMEGOLDVA] CHAR (1) NOT NULL, [C_MEGOLDASIDEJE] DATETIME NULL, [C_TANULOID] INT NOT NULL, [C_HAZIFELADATOKID] INT NOT NULL, [C_INTEZMENYID] INT NOT NULL, [C_TANEVID] INT NOT NULL, [TOROLT] CHAR (1) NOT NULL, [SERIAL] INT NOT NULL, [LASTCHANGED] DATETIME NOT NULL, [CREATED] DATETIME NOT NULL, [MODIFIER] INT NULL, [CREATOR] INT NULL, [ELOZOTANEVIREKORDID] INT NULL, [NNID] INT NULL, CONSTRAINT [PK_TanuloHaziFeladatStatusz] PRIMARY KEY CLUSTERED ([ID] ASC) ); GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[NCI_TanuloHaziFeladatStatusz_TanuloId]...'; GO CREATE NONCLUSTERED INDEX [NCI_TanuloHaziFeladatStatusz_TanuloId] ON [dbo].[T_TANULOHAZIFELADATSTATUSZ]([C_TANULOID] ASC); GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[NCI_TanuloHaziFeladatStatusz_HaziFeladatokId]...'; GO CREATE NONCLUSTERED INDEX [NCI_TanuloHaziFeladatStatusz_HaziFeladatokId] ON [dbo].[T_TANULOHAZIFELADATSTATUSZ]([C_HAZIFELADATOKID] ASC); GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[NCI_TanuloHaziFeladatStatusz_IntezmenyId]...'; GO CREATE NONCLUSTERED INDEX [NCI_TanuloHaziFeladatStatusz_IntezmenyId] ON [dbo].[T_TANULOHAZIFELADATSTATUSZ]([C_INTEZMENYID] ASC); GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[NCI_TanuloHaziFeladatStatusz_TanevId]...'; GO CREATE NONCLUSTERED INDEX [NCI_TanuloHaziFeladatStatusz_TanevId] ON [dbo].[T_TANULOHAZIFELADATSTATUSZ]([C_TANEVID] ASC); GO PRINT N'Creating unnamed constraint on [dbo].[T_SZAMONKERESELOREJELZES]...'; GO ALTER TABLE [dbo].[T_SZAMONKERESELOREJELZES] ADD DEFAULT ('F') FOR [C_ISERTESITESELKULDVE]; GO PRINT N'Creating unnamed constraint on [dbo].[T_TANULOHAZIFELADAT]...'; GO ALTER TABLE [dbo].[T_TANULOHAZIFELADAT] ADD DEFAULT ('F') FOR [C_ISERTESITESELKULDVE]; GO PRINT N'Creating unnamed constraint on [dbo].[T_HAZIFELADATOK]...'; ALTER TABLE [dbo].[T_HAZIFELADATOK] ADD DEFAULT ('F') FOR [C_ISERTESITESELKULDVE]; GO PRINT N'Creating unnamed constraint on [dbo].[T_TANULOHAZIFELADATSTATUSZ]...'; GO ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] ADD DEFAULT ('F') FOR [C_ISMEGOLDVA]; GO PRINT N'Creating unnamed constraint on [dbo].[T_TANULOHAZIFELADATSTATUSZ]...'; GO ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] ADD DEFAULT (getdate()) FOR [CREATED]; GO PRINT N'Creating unnamed constraint on [dbo].[T_TANULOHAZIFELADATSTATUSZ]...'; GO ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] ADD DEFAULT ((0)) FOR [SERIAL]; GO PRINT N'Creating unnamed constraint on [dbo].[T_TANULOHAZIFELADATSTATUSZ]...'; GO ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] ADD DEFAULT ('F') FOR [TOROLT]; GO PRINT N'Creating unnamed constraint on [dbo].[T_TANULOHAZIFELADATSTATUSZ]...'; GO ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] ADD DEFAULT (getdate()) FOR [LASTCHANGED]; GO PRINT N'Creating [dbo].[FK_TanuloHaziFeladatStatusz_TanuloId_REF_Tanulo]...'; GO ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] WITH NOCHECK ADD CONSTRAINT [FK_TanuloHaziFeladatStatusz_TanuloId_REF_Tanulo] FOREIGN KEY ([C_TANULOID]) REFERENCES [dbo].[T_TANULO] ([ID]); GO PRINT N'Creating [dbo].[FK_TanuloHaziFeladatStatusz_HaziFeladatokId_REF_HaziFeladatok]...'; GO ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] WITH NOCHECK ADD CONSTRAINT [FK_TanuloHaziFeladatStatusz_HaziFeladatokId_REF_HaziFeladatok] FOREIGN KEY ([C_HAZIFELADATOKID]) REFERENCES [dbo].[T_HAZIFELADATOK] ([ID]); GO PRINT N'Creating [dbo].[FK_TanuloHaziFeladatStatusz_IntezmenyId_REF_Intezmeny]...'; GO ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] WITH NOCHECK ADD CONSTRAINT [FK_TanuloHaziFeladatStatusz_IntezmenyId_REF_Intezmeny] FOREIGN KEY ([C_INTEZMENYID]) REFERENCES [dbo].[T_INTEZMENY] ([ID]); GO PRINT N'Creating [dbo].[FK_TanuloHaziFeladatStatusz_TanevId_REF_Tanev]...'; GO ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] WITH NOCHECK ADD CONSTRAINT [FK_TanuloHaziFeladatStatusz_TanevId_REF_Tanev] FOREIGN KEY ([C_TANEVID]) REFERENCES [dbo].[T_TANEV] ([ID]); GO PRINT N'Creating [dbo].[FK_Osztaly_AranyJanosProgramTipusId_AlintezmenyId_AltanevId_REF_AranyJanosProgramTipus]...'; GO ALTER TABLE [dbo].[T_OSZTALY] WITH NOCHECK ADD CONSTRAINT [FK_Osztaly_AranyJanosProgramTipusId_AlintezmenyId_AltanevId_REF_AranyJanosProgramTipus] FOREIGN KEY ([C_ARANYJANOSPROGRAMTIPUSID], [C_ALINTEZMENYID], [C_ALTANEVID]) REFERENCES [dbo].[T_ARANYJANOSPROGRAMTIPUS] ([ID], [C_ALINTEZMENYID], [C_ALTANEVID]); GO PRINT N'Creating [dbo].[FK_TanuloEsemeny_FeljegyzoId_REF_Felhasznalo]...'; GO ALTER TABLE [dbo].[T_TANULOESEMENY] WITH NOCHECK ADD CONSTRAINT [FK_TanuloEsemeny_FeljegyzoId_REF_Felhasznalo] FOREIGN KEY ([C_FELJEGYZOID]) REFERENCES [dbo].[T_FELHASZNALO] ([ID]); GO PRINT N'Refreshing [dbo].[T_HAZIFELADATOK_OSSZES]...'; GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[ID].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord egyedi azonosítója, generált IDENTITY(1, 1) (kivéve altáblák esetén, ahol a főtábla ID-ját kapja)', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TANULOHAZIFELADATSTATUSZ', @level2type = N'COLUMN', @level2name = N'ID'; GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[C_INTEZMENYID].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Az intézmény ID-ja, amihez a rekord tartozik', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TANULOHAZIFELADATSTATUSZ', @level2type = N'COLUMN', @level2name = N'C_INTEZMENYID'; GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[C_TANEVID].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A tanév ID-ja, amihez a rekord tartozik', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TANULOHAZIFELADATSTATUSZ', @level2type = N'COLUMN', @level2name = N'C_TANEVID'; GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[TOROLT].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord logikai töröltségét jelző flag', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TANULOHAZIFELADATSTATUSZ', @level2type = N'COLUMN', @level2name = N'TOROLT'; GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[SERIAL].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Minden C# kódból történő módosítás esetén eggyel nő az értéke. Hogy párhuzamos módosítás esetnán ne íródjanak felül az adatok', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TANULOHAZIFELADATSTATUSZ', @level2type = N'COLUMN', @level2name = N'SERIAL'; GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[LASTCHANGED].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N' A rekord utolsó módosításának időpontja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TANULOHAZIFELADATSTATUSZ', @level2type = N'COLUMN', @level2name = N'LASTCHANGED'; GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[CREATED].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord létrehozásának időpontja ', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TANULOHAZIFELADATSTATUSZ', @level2type = N'COLUMN', @level2name = N'CREATED'; GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[MODIFIER].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot utoljára módosító felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TANULOHAZIFELADATSTATUSZ', @level2type = N'COLUMN', @level2name = N'MODIFIER'; GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[CREATOR].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot létrehozó felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TANULOHAZIFELADATSTATUSZ', @level2type = N'COLUMN', @level2name = N'CREATOR'; GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[ELOZOTANEVIREKORDID].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord előző tanévben lévő ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TANULOHAZIFELADATSTATUSZ', @level2type = N'COLUMN', @level2name = N'ELOZOTANEVIREKORDID'; GO PRINT N'Creating [dbo].[T_TANULOHAZIFELADATSTATUSZ].[NNID].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord régi, Neptun Naplóban lévő ID-ja. (migrációval került be)', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TANULOHAZIFELADATSTATUSZ', @level2type = N'COLUMN', @level2name = N'NNID'; GO ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] WITH CHECK CHECK CONSTRAINT [FK_TanuloHaziFeladatStatusz_TanuloId_REF_Tanulo]; ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] WITH CHECK CHECK CONSTRAINT [FK_TanuloHaziFeladatStatusz_HaziFeladatokId_REF_HaziFeladatok]; ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] WITH CHECK CHECK CONSTRAINT [FK_TanuloHaziFeladatStatusz_IntezmenyId_REF_Intezmeny]; ALTER TABLE [dbo].[T_TANULOHAZIFELADATSTATUSZ] WITH CHECK CHECK CONSTRAINT [FK_TanuloHaziFeladatStatusz_TanevId_REF_Tanev]; ALTER TABLE [dbo].[T_OSZTALY] WITH CHECK CHECK CONSTRAINT [FK_Osztaly_AranyJanosProgramTipusId_AlintezmenyId_AltanevId_REF_AranyJanosProgramTipus]; ALTER TABLE [dbo].[T_TANULOESEMENY] WITH CHECK CHECK CONSTRAINT [FK_TanuloEsemeny_FeljegyzoId_REF_Felhasznalo]; GO PRINT N'Update complete.'; GO EXEC dev.uspCreateSchemaViews 'T_TANULOHAZIFELADAT, T_SZAMONKERESELOREJELZES, T_HAZIFELADATOK, T_TANULOHAZIFELADATSTATUSZ, T_OSZTALY' GO EXEC dev.sp_Global_GenerateAsyncAuditTriggerAll GO ALTER QUEUE auditLog.[AuditQueue] WITH ACTIVATION ( STATUS = ON, PROCEDURE_NAME = auditLog.usp_AuditProcessing, MAX_QUEUE_READERS = 10, EXECUTE AS 'Kreta_tech_user' ); GO