GO SET ANSI_NULLS, ANSI_PADDING, ANSI_WARNINGS, ARITHABORT, CONCAT_NULL_YIELDS_NULL, QUOTED_IDENTIFIER ON; SET NUMERIC_ROUNDABORT OFF; GO PRINT N'Altering [dbo].[T_DASHBOARDUZENET]...'; GO ALTER TABLE [dbo].[T_DASHBOARDUZENET] ADD [C_DASHBOARDUZENETKATEGORIAID] INT NOT NULL; GO PRINT N'Creating [dbo].[T_DASHBOARDUZENET].[I_T_4028858_4028857]...'; GO CREATE NONCLUSTERED INDEX [I_T_4028858_4028857] ON [dbo].[T_DASHBOARDUZENET]([C_DASHBOARDUZENETKATEGORIAID] ASC); GO PRINT N'Creating [dbo].[FK_4028858_4028857]...'; GO ALTER TABLE [dbo].[T_DASHBOARDUZENET] WITH NOCHECK ADD CONSTRAINT [FK_4028858_4028857] FOREIGN KEY ([C_DASHBOARDUZENETKATEGORIAID]) REFERENCES [dbo].[T_DASHBOARDUZENETKATEGORIA] ([ID]); GO PRINT N'Altering [dbo].[T_DASHBOARDUZENET].[C_CIM].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'a Dashboard üzenet cím mezoje', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENET', @level2type = N'COLUMN', @level2name = N'C_CIM'; GO PRINT N'Altering [dbo].[T_DASHBOARDUZENET].[C_ERVENYESSEGKEZDETE].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'a Dashboard üzenet ettol az idoponttól látható, ha NULL akkor a kezdetektol', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENET', @level2type = N'COLUMN', @level2name = N'C_ERVENYESSEGKEZDETE'; GO PRINT N'Altering [dbo].[T_DASHBOARDUZENET].[C_ERVENYESSEGVEGE].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'a Dashboard üzenet eddig az idopontig lesz látható', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENET', @level2type = N'COLUMN', @level2name = N'C_ERVENYESSEGVEGE'; GO PRINT N'Altering [dbo].[T_DASHBOARDUZENET].[C_KIEMELTIDOSZAKVEGE].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'az üzenet eddig az idopontig kiemelten az elso helyen fog szerepelni, ezt követoen a sorrendje helyén', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENET', @level2type = N'COLUMN', @level2name = N'C_KIEMELTIDOSZAKVEGE'; GO PRINT N'Altering [dbo].[T_DASHBOARDUZENET].[C_SORREND].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'a Dashboard üzenet sorrendje, hogy kb. hányadikként jelenjen meg a felületen', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENET', @level2type = N'COLUMN', @level2name = N'C_SORREND'; GO PRINT N'Altering [dbo].[T_DASHBOARDUZENET].[C_TARTALOM].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'a Dashboard üzenet tartalma', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENET', @level2type = N'COLUMN', @level2name = N'C_TARTALOM'; GO PRINT N'Creating [dbo].[T_DASHBOARDUZENET].[C_DASHBOARDUZENETKATEGORIAID].[MS_Description]...'; GO EXECUTE sp_addextendedproperty @name = N'MS_Description', @value = N'meghatározza a dashboard üzenet fontosságát', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DASHBOARDUZENET', @level2type = N'COLUMN', @level2name = N'C_DASHBOARDUZENETKATEGORIAID'; GO PRINT N'Checking existing data against newly created constraints'; GO ALTER TABLE [dbo].[T_DASHBOARDUZENET] WITH CHECK CHECK CONSTRAINT [FK_4028858_4028857]; GO PRINT N'Update complete.'; GO -------------------- PRINT '--- intézményi view-k (dbo táblákkal megegyező nevű és a tábla_OSSZES nevűek) frissítése ---' DECLARE @viewname nvarchar(100), @pureview nvarchar(100) DECLARE semaviewk CURSOR LOCAL FOR SELECT '['+TABLE_SCHEMA + '].[' + TABLE_NAME + ']', TABLE_NAME FROM INFORMATION_SCHEMA.TABLES WHERE TABLE_TYPE = 'VIEW' and TABLE_SCHEMA LIKE 'KR[_]%[_]Schema' AND TABLE_NAME in ('T_DASHBOARDUZENET', 'T_DASHBOARDUZENET_OSSZES' ) -- ha csak néhány VIEW frissült, akkor a gyorsabb futásért ide fel lehet sorolni ORDER BY TABLE_SCHEMA, TABLE_NAME OPEN semaviewk FETCH NEXT FROM semaviewk INTO @viewname, @pureview WHILE @@FETCH_STATUS = 0 BEGIN PRINT @viewname EXEC sp_refreshview @viewname FETCH NEXT FROM semaviewk INTO @viewname, @pureview END CLOSE semaviewk DEALLOCATE semaviewk GO -------------------- EXEC dev.sp_Global_GenerateAsyncAuditTriggerAll GO ALTER QUEUE auditLog.[AuditQueue] WITH ACTIVATION ( STATUS = ON, PROCEDURE_NAME = auditLog.usp_AuditProcessing, MAX_QUEUE_READERS = 10, EXECUTE AS 'Kreta_tech_user' ); GO