PRINT N'Dropping Index [dbo].[T_TEREM].[NCI_Terem_MukodesiHelyId]...'; GO DROP INDEX [NCI_Terem_MukodesiHelyId] ON [dbo].[T_TEREM]; GO PRINT N'Dropping Index [dbo].[T_TEREM].[NCI_Terem_ElozotanevirekordId_IntezmenyId]...'; GO DROP INDEX [NCI_Terem_ElozotanevirekordId_IntezmenyId] ON [dbo].[T_TEREM]; GO PRINT N'Dropping Index [dbo].[T_NEMKOTOTTMUNKAIDO].[NCI_NemKotottMunkaido_TulajdonosId]...'; GO DROP INDEX [NCI_NemKotottMunkaido_TulajdonosId] ON [dbo].[T_NEMKOTOTTMUNKAIDO]; GO PRINT N'Dropping Index [dbo].[T_ORARENDIORA].[NCI_OrarendiOra_OraTulajdonosId]...'; GO DROP INDEX [NCI_OrarendiOra_OraTulajdonosId] ON [dbo].[T_ORARENDIORA]; GO PRINT N'Dropping Foreign Key [dbo].[FK_Terem_MukodesiHelyId_REF_MukodesiHely]...'; GO ALTER TABLE [dbo].[T_TEREM] DROP CONSTRAINT [FK_Terem_MukodesiHelyId_REF_MukodesiHely]; GO PRINT N'Dropping Foreign Key [dbo].[FK_NemKotottMunkaido_TulajdonosId_REF_Felhasznalo]...'; GO ALTER TABLE [dbo].[T_NEMKOTOTTMUNKAIDO] DROP CONSTRAINT [FK_NemKotottMunkaido_TulajdonosId_REF_Felhasznalo]; GO PRINT N'Dropping Foreign Key [dbo].[FK_OrarendiOra_OraTulajdonosId_REF_Felhasznalo]...'; GO ALTER TABLE [dbo].[T_ORARENDIORA] DROP CONSTRAINT [FK_OrarendiOra_OraTulajdonosId_REF_Felhasznalo]; GO PRINT N'Altering Table [dbo].[T_NEMKOTOTTMUNKAIDO]...'; GO ALTER TABLE [dbo].[T_NEMKOTOTTMUNKAIDO] DROP COLUMN [C_TULAJDONOSID]; GO PRINT N'Altering Table [dbo].[T_ORARENDIORA]...'; GO ALTER TABLE [dbo].[T_ORARENDIORA] DROP COLUMN [C_ORATULAJDONOSID]; GO PRINT N'Altering Table [dbo].[T_TEREM]...'; GO ALTER TABLE [dbo].[T_TEREM] ALTER COLUMN [C_MUKODESIHELYID] INT NULL; GO ALTER TABLE [dbo].[T_TEREM] ADD [C_DUALISHELYSZINTIPUSID] INT NULL; GO PRINT N'Creating Index [dbo].[T_TEREM].[NCI_Terem_MukodesiHelyId]...'; GO CREATE NONCLUSTERED INDEX [NCI_Terem_MukodesiHelyId] ON [dbo].[T_TEREM]([C_MUKODESIHELYID] ASC); GO PRINT N'Creating Index [dbo].[T_TEREM].[NCI_Terem_ElozotanevirekordId_IntezmenyId]...'; GO CREATE NONCLUSTERED INDEX [NCI_Terem_ElozotanevirekordId_IntezmenyId] ON [dbo].[T_TEREM]([ELOZOTANEVIREKORDID] ASC, [C_INTEZMENYID] ASC) INCLUDE([C_JELLEG], [C_NEV], [C_TEREMFELELOSID], [C_MUKODESIHELYID], [SERIAL], [TOROLT]) WITH (FILLFACTOR = 80); GO PRINT N'Creating Index [dbo].[T_TEREM].[NCI_Terem_IntezmenyId_TanevId_DualisHelyszinTipusId]...'; GO CREATE NONCLUSTERED INDEX [NCI_Terem_IntezmenyId_TanevId_DualisHelyszinTipusId] ON [dbo].[T_TEREM]([C_INTEZMENYID] ASC, [C_TANEVID] ASC, [C_DUALISHELYSZINTIPUSID] ASC); GO PRINT N'Creating Table [dbo].[T_DUALISHELYSZINTIPUS]...'; GO CREATE TABLE [dbo].[T_DUALISHELYSZINTIPUS] ( [ID] INT NOT NULL, [C_ALINTEZMENYID] INT NOT NULL, [C_ALTANEVID] INT NOT NULL, [TOROLT] CHAR (1) NOT NULL, [SERIAL] INT NOT NULL, [LASTCHANGED] DATETIME NOT NULL, [CREATED] DATETIME NOT NULL, [MODIFIER] INT NULL, [CREATOR] INT NULL, [ELOZOTANEVIREKORDID] INT NULL, [ELOZOTANEVIREKORDIDA] INT NULL, CONSTRAINT [PK_DualisHelyszinTipus] PRIMARY KEY CLUSTERED ([ID] ASC, [C_ALINTEZMENYID] ASC, [C_ALTANEVID] ASC) ); GO PRINT N'Creating Index [dbo].[T_DUALISHELYSZINTIPUS].[NCI_DualisHelyszinTipus_AlIntezmenyId]...'; GO CREATE NONCLUSTERED INDEX [NCI_DualisHelyszinTipus_AlIntezmenyId] ON [dbo].[T_DUALISHELYSZINTIPUS]([C_ALINTEZMENYID] ASC); GO PRINT N'Creating Index [dbo].[T_DUALISHELYSZINTIPUS].[NCI_DualisHelyszinTipus_AlTanevId]...'; GO CREATE NONCLUSTERED INDEX [NCI_DualisHelyszinTipus_AlTanevId] ON [dbo].[T_DUALISHELYSZINTIPUS]([C_ALTANEVID] ASC); GO PRINT N'Creating Default Constraint unnamed constraint on [dbo].[T_DUALISHELYSZINTIPUS]...'; GO ALTER TABLE [dbo].[T_DUALISHELYSZINTIPUS] ADD DEFAULT ((0)) FOR [SERIAL]; GO PRINT N'Creating Default Constraint unnamed constraint on [dbo].[T_DUALISHELYSZINTIPUS]...'; GO ALTER TABLE [dbo].[T_DUALISHELYSZINTIPUS] ADD DEFAULT ('F') FOR [TOROLT]; GO PRINT N'Creating Default Constraint unnamed constraint on [dbo].[T_DUALISHELYSZINTIPUS]...'; GO ALTER TABLE [dbo].[T_DUALISHELYSZINTIPUS] ADD DEFAULT (getdate()) FOR [CREATED]; GO PRINT N'Creating Default Constraint unnamed constraint on [dbo].[T_DUALISHELYSZINTIPUS]...'; GO ALTER TABLE [dbo].[T_DUALISHELYSZINTIPUS] ADD DEFAULT (getdate()) FOR [LASTCHANGED]; GO PRINT N'Creating Foreign Key [dbo].[FK_Terem_MukodesiHelyId_REF_MukodesiHely]...'; GO ALTER TABLE [dbo].[T_TEREM] WITH NOCHECK ADD CONSTRAINT [FK_Terem_MukodesiHelyId_REF_MukodesiHely] FOREIGN KEY ([C_MUKODESIHELYID]) REFERENCES [dbo].[T_MUKODESIHELY] ([ID]); GO PRINT N'Creating Foreign Key [dbo].[FK_DualisHelyszinTipus_Id_AlintezmenyId_AltanevId_REF_DictionaryItemBase]...'; GO ALTER TABLE [dbo].[T_DUALISHELYSZINTIPUS] WITH NOCHECK ADD CONSTRAINT [FK_DualisHelyszinTipus_Id_AlintezmenyId_AltanevId_REF_DictionaryItemBase] FOREIGN KEY ([ID], [C_ALINTEZMENYID], [C_ALTANEVID]) REFERENCES [dbo].[T_DICTIONARYITEMBASE] ([ID], [C_INTEZMENYID], [C_TANEVID]); GO PRINT N'Creating Foreign Key [dbo].[FK_DualisHelyszinTipus_AlIntezmenyId_REF_Intezmeny]...'; GO ALTER TABLE [dbo].[T_DUALISHELYSZINTIPUS] WITH NOCHECK ADD CONSTRAINT [FK_DualisHelyszinTipus_AlIntezmenyId_REF_Intezmeny] FOREIGN KEY ([C_ALINTEZMENYID]) REFERENCES [dbo].[T_INTEZMENY] ([ID]); GO PRINT N'Creating Foreign Key [dbo].[FK_DualisHelyszinTipus_AlTanevId_REF_Tanev]...'; GO ALTER TABLE [dbo].[T_DUALISHELYSZINTIPUS] WITH NOCHECK ADD CONSTRAINT [FK_DualisHelyszinTipus_AlTanevId_REF_Tanev] FOREIGN KEY ([C_ALTANEVID]) REFERENCES [dbo].[T_TANEV] ([ID]); GO PRINT N'Creating Foreign Key [dbo].[FK_Terem_DualisHelyszinTipusId_IntezmenyId_TanevId_REF_DualisHelyszinTipus]...'; GO ALTER TABLE [dbo].[T_TEREM] WITH NOCHECK ADD CONSTRAINT [FK_Terem_DualisHelyszinTipusId_IntezmenyId_TanevId_REF_DualisHelyszinTipus] FOREIGN KEY ([C_DUALISHELYSZINTIPUSID], [C_INTEZMENYID], [C_TANEVID]) REFERENCES [dbo].[T_DUALISHELYSZINTIPUS] ([ID], [C_ALINTEZMENYID], [C_ALTANEVID]); GO PRINT N'Creating Extended Property [dbo].[T_DUALISHELYSZINTIPUS].[ID].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord egyedi azonosítója, generált IDENTITY(1, 1) (kivéve altáblák esetén, ahol a főtábla ID-ját kapja)', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DUALISHELYSZINTIPUS', @level2type = N'COLUMN', @level2name = N'ID'; GO PRINT N'Creating Extended Property [dbo].[T_DUALISHELYSZINTIPUS].[C_ALINTEZMENYID].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Az intézmény ID-ja, amihez a rekord tartozik (altábla esetén)', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DUALISHELYSZINTIPUS', @level2type = N'COLUMN', @level2name = N'C_ALINTEZMENYID'; GO PRINT N'Creating Extended Property [dbo].[T_DUALISHELYSZINTIPUS].[C_ALTANEVID].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A tanév ID-ja, amihez a rekord tartozik (altábla esetén)', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DUALISHELYSZINTIPUS', @level2type = N'COLUMN', @level2name = N'C_ALTANEVID'; GO PRINT N'Creating Extended Property [dbo].[T_DUALISHELYSZINTIPUS].[TOROLT].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord logikai töröltségét jelző flag', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DUALISHELYSZINTIPUS', @level2type = N'COLUMN', @level2name = N'TOROLT'; GO PRINT N'Creating Extended Property [dbo].[T_DUALISHELYSZINTIPUS].[SERIAL].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Minden C# kódból történő módosítás esetén eggyel nő az értéke. Hogy párhuzamos módosítás esetnán ne íródjanak felül az adatok', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DUALISHELYSZINTIPUS', @level2type = N'COLUMN', @level2name = N'SERIAL'; GO PRINT N'Creating Extended Property [dbo].[T_DUALISHELYSZINTIPUS].[LASTCHANGED].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N' A rekord utolsó módosításának időpontja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DUALISHELYSZINTIPUS', @level2type = N'COLUMN', @level2name = N'LASTCHANGED'; GO PRINT N'Creating Extended Property [dbo].[T_DUALISHELYSZINTIPUS].[CREATED].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord létrehozásának időpontja ', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DUALISHELYSZINTIPUS', @level2type = N'COLUMN', @level2name = N'CREATED'; GO PRINT N'Creating Extended Property [dbo].[T_DUALISHELYSZINTIPUS].[MODIFIER].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot utoljára módosító felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DUALISHELYSZINTIPUS', @level2type = N'COLUMN', @level2name = N'MODIFIER'; GO PRINT N'Creating Extended Property [dbo].[T_DUALISHELYSZINTIPUS].[CREATOR].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekordot létrehozó felhasználó ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DUALISHELYSZINTIPUS', @level2type = N'COLUMN', @level2name = N'CREATOR'; GO PRINT N'Creating Extended Property [dbo].[T_DUALISHELYSZINTIPUS].[ELOZOTANEVIREKORDID].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord előző tanévben lévő ID-ja', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DUALISHELYSZINTIPUS', @level2type = N'COLUMN', @level2name = N'ELOZOTANEVIREKORDID'; GO PRINT N'Creating Extended Property [dbo].[T_DUALISHELYSZINTIPUS].[ELOZOTANEVIREKORDIDA].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'A rekord előző tanévben lévő ID-ja (altábla esetén) ', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_DUALISHELYSZINTIPUS', @level2type = N'COLUMN', @level2name = N'ELOZOTANEVIREKORDIDA'; GO PRINT N'Creating Extended Property [dbo].[T_TEREM].[C_DUALISHELYSZINTIPUSID].[MS_Description]...'; GO EXECUTE dev.uspAddOrUpdateExtendedProperty @name = N'MS_Description', @value = N'Helyszín típusa', @level0type = N'SCHEMA', @level0name = N'dbo', @level1type = N'TABLE', @level1name = N'T_TEREM', @level2type = N'COLUMN', @level2name = N'C_DUALISHELYSZINTIPUSID'; GO PRINT N'Checking existing data against newly created constraints'; GO ALTER TABLE [dbo].[T_TEREM] WITH CHECK CHECK CONSTRAINT [FK_Terem_MukodesiHelyId_REF_MukodesiHely]; ALTER TABLE [dbo].[T_DUALISHELYSZINTIPUS] WITH CHECK CHECK CONSTRAINT [FK_DualisHelyszinTipus_Id_AlintezmenyId_AltanevId_REF_DictionaryItemBase]; ALTER TABLE [dbo].[T_DUALISHELYSZINTIPUS] WITH CHECK CHECK CONSTRAINT [FK_DualisHelyszinTipus_AlIntezmenyId_REF_Intezmeny]; ALTER TABLE [dbo].[T_DUALISHELYSZINTIPUS] WITH CHECK CHECK CONSTRAINT [FK_DualisHelyszinTipus_AlTanevId_REF_Tanev]; ALTER TABLE [dbo].[T_TEREM] WITH CHECK CHECK CONSTRAINT [FK_Terem_DualisHelyszinTipusId_IntezmenyId_TanevId_REF_DualisHelyszinTipus]; EXEC dev.uspCreateSchemaViews 'T_TEREM, T_DUALISHELYSZINTIPUS, T_NEMKOTOTTMUNKAIDO, T_ORARENDIORA' EXEC dev.sp_Global_GenerateAsyncAuditTriggerAll GO PRINT N'Update complete.'; GO