init
This commit is contained in:
commit
e124a47765
19374 changed files with 9806149 additions and 0 deletions
|
@ -0,0 +1,533 @@
|
|||
--------------------
|
||||
|
||||
CREATE PROCEDURE [dbo].[sp_AddNewSchemaViews]
|
||||
@IntezmenyId int,
|
||||
@IntezmenyAzonosito nvarchar(30),
|
||||
@TanevId int
|
||||
AS
|
||||
BEGIN
|
||||
|
||||
DECLARE @IntezmenyTemplate nvarchar(50) = 'KR_'+@IntezmenyAzonosito
|
||||
DECLARE @Schema nvarchar(50) = @IntezmenyTemplate+'_Schema'
|
||||
DECLARE @SchemaUser nvarchar(50) = @IntezmenyTemplate + '_user'
|
||||
DECLARE @AktivTanev nvarchar(500)
|
||||
DECLARE @Sql nvarchar(max)
|
||||
|
||||
|
||||
/*============================================================================*/
|
||||
/* View : T_DOKUMENTUMKULCSSZOERTEK */
|
||||
/*============================================================================*/
|
||||
/* Package: Kreta */
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMKULCSSZOERTEK', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMKULCSSZOERTEK'''
|
||||
EXEC sp_executesql @Sql
|
||||
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMKULCSSZOERTEK_OSSZES', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMKULCSSZOERTEK_OSSZES'''
|
||||
EXEC sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
ELSE BEGIN
|
||||
/* Ha nem létezik a view, akkor létrehozzuk */
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMKULCSSZOERTEK' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_TANEVID'
|
||||
) > 0
|
||||
BEGIN
|
||||
SET @AktivTanev = N' C_TANEVID = '+ CAST(@TanevId as nvarchar) +' AND '
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
SET @AktivTanev = N''
|
||||
END
|
||||
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMKULCSSZOERTEK' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_INTEZMENYID'
|
||||
) > 0
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMKULCSSZOERTEK */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZOERTEK
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZOERTEK
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'') AND C_INTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMKULCSSZOERTEK_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZOERTEK_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZOERTEK
|
||||
WHERE C_INTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMKULCSSZOERTEK */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZOERTEK
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZOERTEK
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'')'
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMKULCSSZOERTEK_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZOERTEK_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZOERTEK'
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
|
||||
|
||||
/*============================================================================*/
|
||||
/* View : T_IKTATOTTDOKUMENTUM */
|
||||
/*============================================================================*/
|
||||
/* Package: Kreta */
|
||||
IF OBJECT_ID('['+@Schema+'].T_IKTATOTTDOKUMENTUM', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_IKTATOTTDOKUMENTUM'''
|
||||
EXEC sp_executesql @Sql
|
||||
|
||||
IF OBJECT_ID('['+@Schema+'].T_IKTATOTTDOKUMENTUM_OSSZES', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_IKTATOTTDOKUMENTUM_OSSZES'''
|
||||
EXEC sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
ELSE BEGIN
|
||||
/* Ha nem létezik a view, akkor létrehozzuk */
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_IKTATOTTDOKUMENTUM' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_TANEVID'
|
||||
) > 0
|
||||
BEGIN
|
||||
SET @AktivTanev = N' C_TANEVID = '+ CAST(@TanevId as nvarchar) +' AND '
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
SET @AktivTanev = N''
|
||||
END
|
||||
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_IKTATOTTDOKUMENTUM' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_INTEZMENYID'
|
||||
) > 0
|
||||
BEGIN
|
||||
/* T_IKTATOTTDOKUMENTUM */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_IKTATOTTDOKUMENTUM
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_IKTATOTTDOKUMENTUM
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'') AND C_INTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_IKTATOTTDOKUMENTUM_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_IKTATOTTDOKUMENTUM_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_IKTATOTTDOKUMENTUM
|
||||
WHERE C_INTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
/* T_IKTATOTTDOKUMENTUM */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_IKTATOTTDOKUMENTUM
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_IKTATOTTDOKUMENTUM
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'')'
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_IKTATOTTDOKUMENTUM_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_IKTATOTTDOKUMENTUM_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_IKTATOTTDOKUMENTUM'
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
|
||||
|
||||
/*============================================================================*/
|
||||
/* View : T_DOKUMENTUMKULCSSZO */
|
||||
/*============================================================================*/
|
||||
/* Package: Kreta */
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMKULCSSZO', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMKULCSSZO'''
|
||||
EXEC sp_executesql @Sql
|
||||
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMKULCSSZO_OSSZES', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMKULCSSZO_OSSZES'''
|
||||
EXEC sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
ELSE BEGIN
|
||||
/* Ha nem létezik a view, akkor létrehozzuk */
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMKULCSSZO' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_TANEVID'
|
||||
) > 0
|
||||
BEGIN
|
||||
SET @AktivTanev = N' C_TANEVID = '+ CAST(@TanevId as nvarchar) +' AND '
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
SET @AktivTanev = N''
|
||||
END
|
||||
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMKULCSSZO' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_INTEZMENYID'
|
||||
) > 0
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMKULCSSZO */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZO
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZO
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'') AND C_INTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMKULCSSZO_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZO_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZO
|
||||
WHERE C_INTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMKULCSSZO */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZO
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZO
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'')'
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMKULCSSZO_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZO_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZO'
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
|
||||
|
||||
/*============================================================================*/
|
||||
/* View : T_DOKUMENTUMTIPUS */
|
||||
/*============================================================================*/
|
||||
/* Package: Kreta */
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMTIPUS', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMTIPUS'''
|
||||
EXEC sp_executesql @Sql
|
||||
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMTIPUS_OSSZES', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMTIPUS_OSSZES'''
|
||||
EXEC sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
ELSE BEGIN
|
||||
/* Ha nem létezik a view, akkor létrehozzuk */
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMTIPUS' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_ALTANEVID'
|
||||
) > 0
|
||||
BEGIN
|
||||
SET @AktivTanev = N' C_ALTANEVID = '+ CAST(@TanevId as nvarchar) +' AND '
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
SET @AktivTanev = N''
|
||||
END
|
||||
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMTIPUS' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_ALINTEZMENYID'
|
||||
) > 0
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMTIPUS */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMTIPUS
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMTIPUS
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'') AND C_ALINTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMTIPUS_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMTIPUS_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMTIPUS
|
||||
WHERE C_ALINTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMTIPUS */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMTIPUS
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMTIPUS
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'')'
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMTIPUS_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMTIPUS_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMTIPUS'
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
|
||||
|
||||
/*============================================================================*/
|
||||
/* View : T_DOKUMENTUMSTATUSZ */
|
||||
/*============================================================================*/
|
||||
/* Package: Kreta */
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMSTATUSZ', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMSTATUSZ'''
|
||||
EXEC sp_executesql @Sql
|
||||
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMSTATUSZ_OSSZES', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMSTATUSZ_OSSZES'''
|
||||
EXEC sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
ELSE BEGIN
|
||||
/* Ha nem létezik a view, akkor létrehozzuk */
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMSTATUSZ' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_ALTANEVID'
|
||||
) > 0
|
||||
BEGIN
|
||||
SET @AktivTanev = N' C_ALTANEVID = '+ CAST(@TanevId as nvarchar) +' AND '
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
SET @AktivTanev = N''
|
||||
END
|
||||
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMSTATUSZ' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_ALINTEZMENYID'
|
||||
) > 0
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMSTATUSZ */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMSTATUSZ
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMSTATUSZ
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'') AND C_ALINTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMSTATUSZ_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMSTATUSZ_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMSTATUSZ
|
||||
WHERE C_ALINTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMSTATUSZ */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMSTATUSZ
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMSTATUSZ
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'')'
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMSTATUSZ_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMSTATUSZ_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMSTATUSZ'
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
|
||||
|
||||
/*============================================================================*/
|
||||
/* View : T_DOKUMENTUMKULCSSZOTIPUS */
|
||||
/*============================================================================*/
|
||||
/* Package: Kreta */
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMKULCSSZOTIPUS', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMKULCSSZOTIPUS'''
|
||||
EXEC sp_executesql @Sql
|
||||
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMKULCSSZOTIPUS_OSSZES', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMKULCSSZOTIPUS_OSSZES'''
|
||||
EXEC sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
ELSE BEGIN
|
||||
/* Ha nem létezik a view, akkor létrehozzuk */
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMKULCSSZOTIPUS' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_ALTANEVID'
|
||||
) > 0
|
||||
BEGIN
|
||||
SET @AktivTanev = N' C_ALTANEVID = '+ CAST(@TanevId as nvarchar) +' AND '
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
SET @AktivTanev = N''
|
||||
END
|
||||
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMKULCSSZOTIPUS' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_ALINTEZMENYID'
|
||||
) > 0
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMKULCSSZOTIPUS */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZOTIPUS
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZOTIPUS
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'') AND C_ALINTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMKULCSSZOTIPUS_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZOTIPUS_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZOTIPUS
|
||||
WHERE C_ALINTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMKULCSSZOTIPUS */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZOTIPUS
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZOTIPUS
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'')'
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMKULCSSZOTIPUS_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKULCSSZOTIPUS_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKULCSSZOTIPUS'
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
|
||||
|
||||
/*============================================================================*/
|
||||
/* View : T_DOKUMENTUMKATEGORIA */
|
||||
/*============================================================================*/
|
||||
/* Package: Kreta */
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMKATEGORIA', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMKATEGORIA'''
|
||||
EXEC sp_executesql @Sql
|
||||
|
||||
IF OBJECT_ID('['+@Schema+'].T_DOKUMENTUMKATEGORIA_OSSZES', 'V') IS NOT NULL BEGIN
|
||||
SET @Sql = N'EXEC sp_refreshview ''['+@Schema+'].T_DOKUMENTUMKATEGORIA_OSSZES'''
|
||||
EXEC sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
ELSE BEGIN
|
||||
/* Ha nem létezik a view, akkor létrehozzuk */
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMKATEGORIA' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_ALTANEVID'
|
||||
) > 0
|
||||
BEGIN
|
||||
SET @AktivTanev = N' C_ALTANEVID = '+ CAST(@TanevId as nvarchar) +' AND '
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
SET @AktivTanev = N''
|
||||
END
|
||||
|
||||
IF (SELECT COUNT(1)
|
||||
FROM INFORMATION_SCHEMA.COLUMNS
|
||||
WHERE TABLE_NAME = N'T_DOKUMENTUMKATEGORIA' AND TABLE_SCHEMA = 'dbo' AND COLUMN_NAME = 'C_ALINTEZMENYID'
|
||||
) > 0
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMKATEGORIA */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKATEGORIA
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKATEGORIA
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'') AND C_ALINTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMKATEGORIA_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKATEGORIA_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKATEGORIA
|
||||
WHERE C_ALINTEZMENYID = '+CAST(@IntezmenyId as nvarchar)
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
ELSE
|
||||
BEGIN
|
||||
/* T_DOKUMENTUMKATEGORIA */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKATEGORIA
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKATEGORIA
|
||||
WHERE '+@AktivTanev+' (TOROLT = ''F'')'
|
||||
EXECUTE sp_executesql @Sql
|
||||
|
||||
/* T_DOKUMENTUMKATEGORIA_OSSZES */
|
||||
SET @Sql = N'CREATE VIEW ['+@Schema+'].T_DOKUMENTUMKATEGORIA_OSSZES
|
||||
AS
|
||||
SELECT *
|
||||
FROM dbo.T_DOKUMENTUMKATEGORIA'
|
||||
EXECUTE sp_executesql @Sql
|
||||
END
|
||||
END
|
||||
|
||||
|
||||
|
||||
END
|
||||
|
||||
GO
|
||||
|
||||
|
||||
--------------------
|
||||
|
||||
|
||||
DECLARE intezmenytanevekCursor CURSOR LOCAL FOR
|
||||
SELECT T_INTEZMENY.ID, T_INTEZMENY.C_AZONOSITO, T_TANEV.ID
|
||||
FROM T_INTEZMENY
|
||||
INNER JOIN T_TANEV ON T_TANEV.C_INTEZMENYID = T_INTEZMENY.ID
|
||||
WHERE T_TANEV.C_AKTIV = 'T' AND T_INTEZMENY.TOROLT = 'F'
|
||||
ORDER BY T_INTEZMENY.ID
|
||||
|
||||
DECLARE @intezmenyId int, @intezmenyAzonosito nvarchar(30), @tanevId int
|
||||
|
||||
OPEN intezmenytanevekCursor
|
||||
FETCH NEXT FROM intezmenytanevekCursor INTO @intezmenyId, @intezmenyAzonosito, @tanevId
|
||||
|
||||
WHILE @@FETCH_STATUS = 0
|
||||
BEGIN
|
||||
PRINT 'INTÉZMÉNY ID: ' + CAST(@intezmenyId AS NVARCHAR(10)) + ', INTÉZMÉNY AZONOSÍTÓ: ' + CAST(@intezmenyAzonosito AS NVARCHAR(30)) + ', TANÉV ID: ' + CAST(@tanevId AS NVARCHAR(10))
|
||||
EXEC sp_AddNewSchemaViews @IntezmenyId = @intezmenyId, @IntezmenyAzonosito = @intezmenyAzonosito, @TanevId = @tanevId
|
||||
|
||||
FETCH NEXT FROM intezmenytanevekCursor INTO @intezmenyId, @intezmenyAzonosito, @tanevId
|
||||
END
|
||||
|
||||
CLOSE intezmenytanevekCursor
|
||||
DEALLOCATE intezmenytanevekCursor
|
||||
|
||||
GO
|
||||
|
||||
|
||||
--------------------
|
||||
|
||||
|
||||
DROP PROCEDURE [dbo].[sp_AddNewSchemaViews]
|
||||
GO
|
||||
|
Loading…
Add table
Add a link
Reference in a new issue